A 1992 Electric Power Research Institute study identified nuclear instrumentation and control (I&C) systems as major contributors to plant operating and maintenance (O&M) costs as well as the leading cause of licensee event reports.
To address system performance and reliability, 金博体育 has provided nuclear field services for many years, supporting I&C system projects from design through development and implementation, with ongoing preventive maintenance. 金博体育鈥檚 field service personnel are highly trained and qualified professionals with worldwide experience, and the skills and abilities to perform a variety of quality-oriented field services.
金博体育 provides a wide range of I&C services, including the following:
Analog Flux Mapping System (AFMS) Service
This service incorporates AFMS preventive maintenance with system testing. 金博体育 personnel perform services in the three distinct areas of drives, five to ten paths switches and the console.
Digital Metal Impact Monitoring System (DMIMS) Maintenance and Baseline Acquisition Service
金博体育鈥檚 experienced and qualified personnel perform detailed maintenance service for the DMIMS. Routine activities are performed in and out of containment for component repairs. As an option, baseline data signature acquisition can be performed with the base-scope DMIMS maintenance service.
Rod Control Enhanced Maintenance Service
This service maximizes trouble-free operation of the rod control system during normal plant operation. The service incorporates updated predictive and preventive maintenance technology of the rod control system individual printed circuit (PC) cards, power cabinets, DC hold cabinet and logic cabinet.
金博体育 has the resources to supply qualified personnel to perform predictive analysis using thermographic studies system hardware, and trending data collected using PC card repairs. Preventive maintenance is done by using the 金博体育 automated board test system to verify PC cards, data collection and report generation. 金博体育 also provides personnel and necessary equipment 鈥 including test equipment 鈥 for preventive maintenance and PC 鈥渢in whisker鈥 inspections.
Rod Drive Motor Generator Controller Maintenance Service
This service incorporates detailed maintenance for the rod control motor generator set controller and its associated control and protection circuitry. It includes verification of proper relay settings, energized voltage regulator and synchronizer testing, adjustments of various system components, cleaning motor generator control cabinets, and general hardware maintenance.
Rod Position Indication (RPI) System Repair Service
The RPI system repair service covers the inspection, repair and testing proposed for the plant. 金博体育 provides engineers and connector specialists experienced in troubleshooting the RPI system. 金博体育 also provides special test equipment needed to test in-containment cable and connector portions of the systems, along with documentation.
Solid State Protection System (SSPS) Maintenance Service
金博体育 now offers a comprehensive SSPS maintenance service designed to test PC cards, clean system cabinets, provide general hardware maintenance, confirm energized system performance and conduct thermography scans.
The 金博体育 automated board test system is a proven technology that has been used for over a decade to verify PC cards used in 金博体育 I&C systems. This technology has been expanded to include the 金博体育 SSPS. Preventative maintenance is done by verifying PC cards, repairing/replacing degraded or damaged board components, collecting data and generating reports. 金博体育 provides experienced and qualified personnel and procedures to complete energized and de-energized system testing as well as component replacement/repair, if needed.
Control Rod Drive Mechanism (CRDM) Current Trace Data Collection Service
This service collects and analyzes CRDM current trace data for proper profiles. Current trace amplitude as well as sequence timing are checked against expected values. These data can be used to trend gripper opening and closing times.
Reactor Vessel Level Instrumentation System/Inadequate Core-cooling Monitor (RVLIS/ICCM) Maintenance Services
The RVLIS/ICCM maintenance services consist of five steps to verify system operation. These steps include: calibration, isolator check-out, process electronics, resistance temperature device (RTD) check-out and system function test. 金博体育 provides experienced and qualified personnel, procedures, test equipment and tooling to perform these services.
Disconnect/reconnect Reactor Vessel Head Mounted Instrumentation Services
Experienced, qualified personnel disconnect/reconnect the CRDM, RPI, in-core thermocouples and CRDM vent fan power cables. 金博体育 also provides pre-disconnect, disconnect, and reconnect testing under the 金博体育 disconnect/reconnect procedure.
Cable and Connector Upgrade Services
金博体育 offers unique customer-specific cable and connector upgrades for the different scenarios each customer may encounter.
Normal age degradation of materials and support components can lead to functional problems, increasing operation costs, as well as the probability and length of planned and/or unscheduled outage time. A variety of problems with ARPI, DRPI, CRDM or NIS systems directly attributable to cable and connector degradation have been reported.
NIS Services
金博体育 offers an installation service for NIS crimp-on style connectors that are used to replace the amphenol-insulated triaxial jacks and plugs. As an alternative, hands-on training for assembling the connectors can also be provided. Other services include installing the detector moderator and performing failure analysis for NIS detectors.
In-core Thermocouple Replacement and Connector Installation Services
During plant outages, in-core thermocouples are frequently damaged and made inoperative. This usually occurs while thermocouples are being handled as the reactor head is assembled and disassembled. During reactor operation, thermocouples fail because of moisture ingression or excessive vibration. Using 金博体育 field service specialists experienced in reactor vessel thermocouple system problems to troubleshoot and repair the system is a good way of applying as-low-as-reasonably-achievable (ALARA) principles, minimizing outage delays, maximizing manpower resources and providing maximum system reliability.
Pressurizer Heater Connector Repair Service
This service utilizes established methods to repair damaged, broken or otherwise inadequate pressurizer heater electrical terminations. The service includes change-out of broken insulating ceramics, replacement of the lugs on the heater pins, and partial or full replacement of the original rubber insulation boots. 金博体育 provides all necessary tools, test equipment and qualified personnel to perform this service.
AMSAC Calibration and Maintenance Service
The AMSAC* calibration and maintenance service includes calibrating process electronics and a system functional test. 金博体育 provides experienced and qualified personnel, procedures and tooling to perform these services.
Ultrasonic Level Monitoring System (ULMS) Advisory Service
金博体育 provides advisory services relating to the O&M of the ULMS. These services include a functional system check, verification of proper installation of the transducer unit for signal strength, checkout of the pulsar pre-amps, checkout of the processors electronics, and verification of the control room indicator.
Installation and Start-up for I&C and Protection System Upgrade Services
The following is a summary of the types of installation support provided by the 金博体育鈥檚 field service group.
Services range from advisory to full-scope installation and testing. Specifics for each customer鈥檚 needs and situation can be provided.
7300 Process I&C System Service
At 金博体育, the field service engineers and technicians can upgrade field change notices and functionally check, troubleshoot and repair the 7300 Process I&C system equipment.
DRPI System Maintenance Service
The DRPI system service includes cleaning, inspecting and testing all DRPI circuit boards, cabinets and power supplies to maximize system reliability. This service utilizes the 金博体育 automated board test system to perform detailed testing of the DRPI system circuit boards. The depth of this testing not only provides a detailed functional verification, but lets 金博体育 perform preventive maintenance by identifying component degradation that could eventually cause a failure if not replaced. Post-maintenance energized testing is also performed with the system configured normally. 金博体育 provides all necessary tools, specialized test equipment, qualified replacement circuit components and qualified personnel to perform this service.
听
*The 鈥淎鈥 in AMSAC stands for 鈥渁nticipated transient without scram.鈥漈he 鈥淢SAC鈥 stands for 鈥渕itigation signal actuation circuitry.鈥
Ovation is a registered trademark of Emerson Electric Company. Other names may be trademarks of their respective owners.